cucsVnicFcOperVcon
Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcOperVcon
OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.11.1.24
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS vnic:Fc:operVcon managed object property
What is cucsVnicFcOperVcon?
This OID returns the virtual connection (vCon) assignment for a Fibre Channel vNIC on the physical adapter, as actually resolved and applied, carried as a short text string. An admin uses this to know which of the adapter's internal virtual connections this Fibre Channel vNIC is mapped to, which determines how its traffic is load-balanced across the physical adapter's uplinks. For example, if two vNICs on the same adapter are both pinned to the same vCon, an admin can spot that imbalance by comparing this field across the affected Fibre Channel vNIC objects.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.11.1.24 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcOperVcon
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.11.1.24.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcOperVcon.1
Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcOperVcon OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.53 | cucsVnicObjects | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.11 | cucsVnicFcTable | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.11.1 | cucsVnicFcEntry | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.11.1.24 | cucsVnicFcOperVcon | CISCO-UNIFIED-COMPUTING-VNIC-MIB |