CISCO-UNIFIED-COMPUTING-VNIC-MIB :: cucsVnicFcOperHostPort

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-VNIC-MIBcucsVnicFcOperHostPort

cucsVnicFcOperHostPort

Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcOperHostPort

OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.11.1.38

Node type: OBJECT-TYPE

Type: CucsVnicVnicOperHostPort

Access: read-only

Description: Cisco UCS vnic:Fc:operHostPort managed object property

What is cucsVnicFcOperHostPort?

This OID returns the fabric interconnect host port this interface is actually using at runtime, carried as a CucsVnicVnicOperHostPort-typed value. An admin compares this operational value against the administratively requested port to confirm the interface actually pinned where it was supposed to. For example, if traffic isn't landing on the expected uplink, an admin checks this field on the Fibre Channel vNIC to see whether it actually resolved to a different host port than requested.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.11.1.38
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcOperHostPort

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.11.1.38.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcOperHostPort.1

Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcOperHostPort OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.53cucsVnicObjectsCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.11cucsVnicFcTableCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.11.1cucsVnicFcEntryCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.11.1.38cucsVnicFcOperHostPortCISCO-UNIFIED-COMPUTING-VNIC-MIB