All MIBs › CISCO-UNIFIED-COMPUTING-VNIC-MIB › cucsVnicFcNodeIdentPoolName
cucsVnicFcNodeIdentPoolName
Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcNodeIdentPoolName
OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.14.1.6
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS vnic:FcNode:identPoolName managed object property
What is cucsVnicFcNodeIdentPoolName?
This OID returns the name of the identity pool feeding addresses to a Fibre Channel node, as administratively configured, carried as a short text string. An admin uses this to know which WWN/WWPN or address pool is supplying identities to this Fibre Channel node, which matters when tracing where a specific address value in the fabric actually came from. For example, if two servers show conflicting addresses, an admin checks this pool name on each Fibre Channel node to see whether they were drawing from the same pool or from different, misconfigured ones.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.14.1.6 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcNodeIdentPoolName
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.14.1.6.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcNodeIdentPoolName.1
Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcNodeIdentPoolName OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.53 | cucsVnicObjects | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.14 | cucsVnicFcNodeTable | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.14.1 | cucsVnicFcNodeEntry | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.14.1.6 | cucsVnicFcNodeIdentPoolName | CISCO-UNIFIED-COMPUTING-VNIC-MIB |