CISCO-UNIFIED-COMPUTING-VNIC-MIB :: cucsVnicFcCdnPropInSync

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-VNIC-MIBcucsVnicFcCdnPropInSync

cucsVnicFcCdnPropInSync

Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcCdnPropInSync

OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.11.1.42

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Cisco UCS vnic:Fc:cdnPropInSync managed object property

What is cucsVnicFcCdnPropInSync?

This OID reports, as a true/false flag, whether the Consistent Device Naming property on a Fibre Channel vNIC is currently in sync between what UCS Manager has configured and what has actually been applied. An admin checks this after changing a CDN name to confirm the change has actually taken effect rather than being stuck pending a server reboot or service profile re-association. For example, if this value shows out-of-sync after a CDN rename, an admin knows the server likely needs to be rebooted or the profile re-applied before the new name takes effect in the OS.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.11.1.42
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcCdnPropInSync

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.11.1.42.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcCdnPropInSync.1

Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcCdnPropInSync OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.53cucsVnicObjectsCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.11cucsVnicFcTableCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.11.1cucsVnicFcEntryCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.11.1.42cucsVnicFcCdnPropInSyncCISCO-UNIFIED-COMPUTING-VNIC-MIB