All MIBs › CISCO-UNIFIED-COMPUTING-VNIC-MIB › cucsVnicFcAdminCdnName
cucsVnicFcAdminCdnName
Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcAdminCdnName
OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.11.1.39
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS vnic:Fc:adminCdnName managed object property
What is cucsVnicFcAdminCdnName?
This OID returns the Consistent Device Naming (CDN) label presented by a Fibre Channel vNIC to the server's OS, as administratively configured, carried as a short text string. An admin sets this so the OS shows a predictable, human-chosen interface name instead of a generic OS-assigned one, which matters when scripting network configuration across many identical servers. For example, if an admin expects the OS to see this vHBA as "SAN-A" but instead sees a generic name, checking this field on the Fibre Channel vNIC confirms whether CDN was actually applied.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.11.1.39 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcAdminCdnName
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.11.1.39.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcAdminCdnName.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsVnicFcAdminCdnName.1
Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicFcAdminCdnName OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.53 | cucsVnicObjects | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.11 | cucsVnicFcTable | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.11.1 | cucsVnicFcEntry | CISCO-UNIFIED-COMPUTING-VNIC-MIB |
| 1.3.6.1.4.1.9.9.719.1.53.11.1.39 | cucsVnicFcAdminCdnName | CISCO-UNIFIED-COMPUTING-VNIC-MIB |