CISCO-UNIFIED-COMPUTING-VNIC-MIB :: cucsVnicEtherOperPinToGroupName

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-VNIC-MIBcucsVnicEtherOperPinToGroupName

cucsVnicEtherOperPinToGroupName

Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicEtherOperPinToGroupName

OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.9.1.33

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS vnic:Ether:operPinToGroupName managed object property

What is cucsVnicEtherOperPinToGroupName?

This read-only SnmpAdminString value reports the operational (currently in-effect, resolved) value of 'pinToGroupName' for this vNIC (virtual Ethernet NIC) instance, as opposed to whatever value was administratively requested. UCS Manager separates admin-requested settings from the operational value actually applied after policy resolution, so this field is what an admin should trust when checking what a vNIC (virtual Ethernet NIC) instance is really doing right now, especially if the admin-side setting and this operational value ever disagree. For the vNIC named 'eth0' on service profile 'SP-WEB03', pinned to fabric interconnect A with a 9000-byte MTU, if the admin-configured value pointed at a policy that had since been deleted, this operational OID would show the fallback value UCS Manager actually resolved to and is currently using.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.9.1.33
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicEtherOperPinToGroupName

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.9.1.33.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicEtherOperPinToGroupName.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsVnicEtherOperPinToGroupName.1

Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicEtherOperPinToGroupName OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.53cucsVnicObjectsCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.9cucsVnicEtherTableCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.9.1cucsVnicEtherEntryCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.9.1.33cucsVnicEtherOperPinToGroupNameCISCO-UNIFIED-COMPUTING-VNIC-MIB