CISCO-UNIFIED-COMPUTING-VNIC-MIB :: cucsVnicDynamicConPolicyRefDn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-VNIC-MIBcucsVnicDynamicConPolicyRefDn

cucsVnicDynamicConPolicyRefDn

Module: CISCO-UNIFIED-COMPUTING-VNIC-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicDynamicConPolicyRefDn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.53.47.1.2

Node type: OBJECT-TYPE

Type: CucsManagedObjectDn

Access: read-only

Description: Cisco UCS vnic:DynamicConPolicyRef:dn managed object property

What is cucsVnicDynamicConPolicyRefDn?

This read-only CucsManagedObjectDn value is the Distinguished Name (DN) of a Dynamic Connection Policy Reference object — the full hierarchical path UCS Manager uses to uniquely address one specific Dynamic Connection Policy Reference instance in its management-information tree. Since a UCS domain can contain many Dynamic Connection Policy Reference instances (one row per service profile's reference to a dynamic connection policy), the DN is what lets monitoring tools or scripts pin an SNMP row to the exact instance it describes rather than just the object type. For example, an admin troubleshooting a service profile whose Dynamic Connection Policy Reference names 'VMFEX-24dvNIC' as the policy actually applied would read this OID to get a DN like 'org-root/...dn', letting them jump straight to that instance in UCS Manager instead of searching through the whole tree.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.47.1.2
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicDynamicConPolicyRefDn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.53.47.1.2.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicDynamicConPolicyRefDn.1

Start monitoring Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-VNIC-MIB::cucsVnicDynamicConPolicyRefDn OID value, configure state conditions and alerts, and monitor any Cisco UCS blade/rack servers and fabric interconnects (vNIC/vHBA) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.53cucsVnicObjectsCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.47cucsVnicDynamicConPolicyRefTableCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.47.1cucsVnicDynamicConPolicyRefEntryCISCO-UNIFIED-COMPUTING-VNIC-MIB
1.3.6.1.4.1.9.9.719.1.53.47.1.2cucsVnicDynamicConPolicyRefDnCISCO-UNIFIED-COMPUTING-VNIC-MIB