All MIBs › CISCO-UNIFIED-COMPUTING-TOP-MIB › cucsTopSysDefaultsRn
cucsTopSysDefaultsRn
Module: CISCO-UNIFIED-COMPUTING-TOP-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-TOP-MIB::cucsTopSysDefaultsRn
OID (numeric): 1.3.6.1.4.1.9.9.719.1.49.4.1.3
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS top:SysDefaults:rn managed object property
What is cucsTopSysDefaultsRn?
This is the Relative Name (RN), a read-only string that distinguishes one instance of the SysDefaults object, which holds the domain-wide default settings applied when no more specific policy overrides them from its sibling instances under the same parent container. Because UCS Manager builds each object's full DN by concatenating RNs down the management tree, this value is the local naming piece an admin needs to understand how the object is addressed relative to its parent. For example, when a new service profile or pool is created without explicit settings and inherits domain defaults instead, comparing RNs lets an admin tell apart two sibling objects of this same class that share the same parent.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.49.4.1.3 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-TOP-MIB::cucsTopSysDefaultsRn
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.49.4.1.3.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-TOP-MIB::cucsTopSysDefaultsRn.1
Start monitoring Cisco UCS blade server chassis / fabric interconnect with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-TOP-MIB::cucsTopSysDefaultsRn OID value, configure state conditions and alerts, and monitor any Cisco UCS blade server chassis / fabric interconnect from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.49 | cucsTopObjects | CISCO-UNIFIED-COMPUTING-TOP-MIB |
| 1.3.6.1.4.1.9.9.719.1.49.4 | cucsTopSysDefaultsTable | CISCO-UNIFIED-COMPUTING-TOP-MIB |
| 1.3.6.1.4.1.9.9.719.1.49.4.1 | cucsTopSysDefaultsEntry | CISCO-UNIFIED-COMPUTING-TOP-MIB |
| 1.3.6.1.4.1.9.9.719.1.49.4.1.3 | cucsTopSysDefaultsRn | CISCO-UNIFIED-COMPUTING-TOP-MIB |