CISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB :: cucsSysdebugLogControlEpFsmRmtInvRslt

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-SYSDEBUG-MIBcucsSysdebugLogControlEpFsmRmtInvRslt

cucsSysdebugLogControlEpFsmRmtInvRslt

Module: CISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB::cucsSysdebugLogControlEpFsmRmtInvRslt

OID (numeric): 1.3.6.1.4.1.9.9.719.1.47.10.1.9

Node type: OBJECT-TYPE

Type: CucsConditionRemoteInvRslt

Access: read-only

Description: Cisco UCS sysdebug:LogControlEp:fsmRmtInvRslt managed object property

What is cucsSysdebugLogControlEpFsmRmtInvRslt?

This enumerated field reports the result code of a remote invocation made as part of the FSM running on this log-control endpoint, which holds the overall internal debug-logging configuration for a UCS endpoint. An admin checks this value to see at a glance whether the remote portion of the workflow behind this log-control endpoint succeeded or failed, without parsing free-text error fields. For example, a non-success value here alongside a populated FsmRmtInvErrDescr confirms the remote call tied to this log-control endpoint's operation did not go through.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.47.10.1.9
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB::cucsSysdebugLogControlEpFsmRmtInvRslt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.47.10.1.9.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB::cucsSysdebugLogControlEpFsmRmtInvRslt.1

Start monitoring Cisco UCS Manager-managed blade/rack servers and fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB::cucsSysdebugLogControlEpFsmRmtInvRslt OID value, configure state conditions and alerts, and monitor any Cisco UCS Manager-managed blade/rack servers and fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.47cucsSysdebugObjectsCISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB
1.3.6.1.4.1.9.9.719.1.47.10cucsSysdebugLogControlEpTableCISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB
1.3.6.1.4.1.9.9.719.1.47.10.1cucsSysdebugLogControlEpEntryCISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB
1.3.6.1.4.1.9.9.719.1.47.10.1.9cucsSysdebugLogControlEpFsmRmtInvRsltCISCO-UNIFIED-COMPUTING-SYSDEBUG-MIB