All MIBs › CISCO-UNIFIED-COMPUTING-SW-MIB › cucsSwVsanMonTrafDir
cucsSwVsanMonTrafDir
Module: CISCO-UNIFIED-COMPUTING-SW-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwVsanMonTrafDir
OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.35.1.11
Node type: OBJECT-TYPE
Type: CucsFabricTrafficDirection
Access: read-only
Description: Cisco UCS sw:Vsan:monTrafDir managed object property
What is cucsSwVsanMonTrafDir?
This reports the monitoring traffic direction configured for this Vsan, indicating whether ingress, egress, or both directions of traffic on this VLAN/VSAN are being mirrored for a SPAN/monitoring session. An admin setting up traffic capture for troubleshooting needs this field to confirm the Vsan is actually mirroring the direction of traffic they intend to inspect. For example, an admin trying to capture only inbound traffic on a Vsan would expect this field to show a receive-only direction, not both directions.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.35.1.11 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwVsanMonTrafDir
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.35.1.11.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwVsanMonTrafDir.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwVsanMonTrafDir OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.46 | cucsSwObjects | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.35 | cucsSwVsanTable | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.35.1 | cucsSwVsanEntry | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.35.1.11 | cucsSwVsanMonTrafDir | CISCO-UNIFIED-COMPUTING-SW-MIB |