All MIBs › CISCO-UNIFIED-COMPUTING-SW-MIB › cucsSwNetflowMonSessionPeerDn
cucsSwNetflowMonSessionPeerDn
Module: CISCO-UNIFIED-COMPUTING-SW-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwNetflowMonSessionPeerDn
OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.77.1.8
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS sw:NetflowMonSession:peerDn managed object property
What is cucsSwNetflowMonSessionPeerDn?
This OID reports the Distinguished Name of the peer object linked to this NetflowMonSession instance, tying it to its counterpart on the other fabric interconnect or link side. An admin uses this to trace that NetFlow monitoring session across a redundant pair of fabric interconnects, confirming that the object on switch A is correctly paired with its counterpart rather than orphaned after a cabling or config change. If the value is empty or points to a nonexistent object, that signals the NetflowMonSession instance currently has no valid peer, which is worth checking after a fabric interconnect reboot or cable swap.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.77.1.8 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwNetflowMonSessionPeerDn
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.77.1.8.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwNetflowMonSessionPeerDn.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwNetflowMonSessionPeerDn OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.46 | cucsSwObjects | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.77 | cucsSwNetflowMonSessionTable | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.77.1 | cucsSwNetflowMonSessionEntry | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.77.1.8 | cucsSwNetflowMonSessionPeerDn | CISCO-UNIFIED-COMPUTING-SW-MIB |