All MIBs › CISCO-UNIFIED-COMPUTING-SW-MIB › cucsSwFcSanPcType
cucsSwFcSanPcType
Module: CISCO-UNIFIED-COMPUTING-SW-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanPcType
OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.26.1.16
Node type: OBJECT-TYPE
Type: CucsSwSanPcType
Access: read-only
Description: Cisco UCS sw:FcSanPc:type managed object property
What is cucsSwFcSanPcType?
This OID, typed as CucsSwSanPcType, reports the specific type classification UCS Manager has assigned to that FC SAN port channel. An admin uses this type value to distinguish this FcSanPc instance's role or category from other instances that share the same class but serve a different purpose on the fabric. Filtering a table of FcSanPc rows by this type value lets an admin isolate, for example, only the physical uplinks versus the port-channel members within the same class.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.26.1.16 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanPcType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.26.1.16.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanPcType.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanPcType OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.46 | cucsSwObjects | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.26 | cucsSwFcSanPcTable | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.26.1 | cucsSwFcSanPcEntry | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.26.1.16 | cucsSwFcSanPcType | CISCO-UNIFIED-COMPUTING-SW-MIB |