All MIBs › CISCO-UNIFIED-COMPUTING-SW-MIB › cucsSwFcSanPcMonTrafDir
cucsSwFcSanPcMonTrafDir
Module: CISCO-UNIFIED-COMPUTING-SW-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanPcMonTrafDir
OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.26.1.17
Node type: OBJECT-TYPE
Type: CucsFabricTrafficDirection
Access: read-only
Description: Cisco UCS sw:FcSanPc:monTrafDir managed object property
What is cucsSwFcSanPcMonTrafDir?
This OID, typed as CucsFabricTrafficDirection, reports which traffic direction (ingress, egress, or both) that FC SAN port channel is configured to monitor. An admin setting up SPAN-style traffic monitoring on a port channel needs this value to confirm the capture is actually watching the direction relevant to the problem being diagnosed. If a FcSanPc is configured to monitor only ingress traffic but the suspected issue is outbound congestion, the admin would need to change this setting to see the relevant packets.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.26.1.17 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanPcMonTrafDir
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.26.1.17.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanPcMonTrafDir.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanPcMonTrafDir OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.46 | cucsSwObjects | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.26 | cucsSwFcSanPcTable | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.26.1 | cucsSwFcSanPcEntry | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.26.1.17 | cucsSwFcSanPcMonTrafDir | CISCO-UNIFIED-COMPUTING-SW-MIB |