CISCO-UNIFIED-COMPUTING-SW-MIB :: cucsSwFcSanMonLocale

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-SW-MIBcucsSwFcSanMonLocale

cucsSwFcSanMonLocale

Module: CISCO-UNIFIED-COMPUTING-SW-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanMonLocale

OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.25.1.4

Node type: OBJECT-TYPE

Type: CucsSwMonDomainLocale

Access: read-only

Description: Cisco UCS sw:FcSanMon:locale managed object property

What is cucsSwFcSanMonLocale?

This OID, typed as CucsSwMonDomainLocale, classifies whether that FC SAN monitor session belongs to the internal (UCS-managed) or external (uplink) side of the fabric. An admin uses this classification to separate traffic or objects that originate inside the UCS domain from those that cross out to the external network or SAN, which matters when isolating a fault to one side of the boundary. A FcSanMon entry reporting an external locale points the admin toward the uplink-facing side of the fabric interconnect when chasing a connectivity issue.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.25.1.4
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanMonLocale

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.25.1.4.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanMonLocale.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanMonLocale OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.46cucsSwObjectsCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.25cucsSwFcSanMonTableCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.25.1cucsSwFcSanMonEntryCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.25.1.4cucsSwFcSanMonLocaleCISCO-UNIFIED-COMPUTING-SW-MIB