All MIBs › CISCO-UNIFIED-COMPUTING-SW-MIB › cucsSwFcSanMonLocale
cucsSwFcSanMonLocale
Module: CISCO-UNIFIED-COMPUTING-SW-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanMonLocale
OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.25.1.4
Node type: OBJECT-TYPE
Type: CucsSwMonDomainLocale
Access: read-only
Description: Cisco UCS sw:FcSanMon:locale managed object property
What is cucsSwFcSanMonLocale?
This OID, typed as CucsSwMonDomainLocale, classifies whether that FC SAN monitor session belongs to the internal (UCS-managed) or external (uplink) side of the fabric. An admin uses this classification to separate traffic or objects that originate inside the UCS domain from those that cross out to the external network or SAN, which matters when isolating a fault to one side of the boundary. A FcSanMon entry reporting an external locale points the admin toward the uplink-facing side of the fabric interconnect when chasing a connectivity issue.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.25.1.4 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanMonLocale
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.25.1.4.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanMonLocale.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanMonLocale OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.46 | cucsSwObjects | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.25 | cucsSwFcSanMonTable | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.25.1 | cucsSwFcSanMonEntry | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.25.1.4 | cucsSwFcSanMonLocale | CISCO-UNIFIED-COMPUTING-SW-MIB |