CISCO-UNIFIED-COMPUTING-SW-MIB :: cucsSwFcSanEpIfType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-SW-MIBcucsSwFcSanEpIfType

cucsSwFcSanEpIfType

Module: CISCO-UNIFIED-COMPUTING-SW-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanEpIfType

OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.24.1.8

Node type: OBJECT-TYPE

Type: CucsSwPIoEpIfType

Access: read-only

Description: Cisco UCS sw:FcSanEp:ifType managed object property

What is cucsSwFcSanEpIfType?

This CucsSwPIoEpIfType field reports the physical interface type of an FC SAN endpoint — one FC interface participating in the fabric interconnect's uplink connection to the external SAN. An admin uses ifType to know what kind of port this endpoint actually is, since different port types carry different expected behavior and troubleshooting steps. For example, the ifType value tells the admin whether they're looking at a native FC port versus another supported interface type before digging further into its statistics.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.24.1.8
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanEpIfType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.24.1.8.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanEpIfType.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanEpIfType OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.46cucsSwObjectsCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.24cucsSwFcSanEpTableCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.24.1cucsSwFcSanEpEntryCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.24.1.8cucsSwFcSanEpIfTypeCISCO-UNIFIED-COMPUTING-SW-MIB