All MIBs › CISCO-UNIFIED-COMPUTING-SW-MIB › cucsSwFcSanBorderFsmFlags
cucsSwFcSanBorderFsmFlags
Module: CISCO-UNIFIED-COMPUTING-SW-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanBorderFsmFlags
OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.22.1.21
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS sw:FcSanBorder:fsmFlags managed object property
What is cucsSwFcSanBorderFsmFlags?
This SnmpAdminString field holds internal flag bits UCSM sets while running the FSM tied to an FC SAN border — the uplink boundary where a UCS fabric interconnect connects out into the external Fibre Channel SAN. These flags are largely for UCSM's own internal bookkeeping of the FSM's execution, but they can help distinguish otherwise-identical FSM runs when comparing multiple instances. For example, an admin correlating repeated FSM runs on the same object could use differing flag values to tell one execution attempt apart from another.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.22.1.21 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanBorderFsmFlags
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.22.1.21.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanBorderFsmFlags.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcSanBorderFsmFlags OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.46 | cucsSwObjects | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.22 | cucsSwFcSanBorderTable | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.22.1 | cucsSwFcSanBorderEntry | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.22.1.21 | cucsSwFcSanBorderFsmFlags | CISCO-UNIFIED-COMPUTING-SW-MIB |