CISCO-UNIFIED-COMPUTING-SW-MIB :: cucsSwFcMonSrcEpIfRole

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-SW-MIBcucsSwFcMonSrcEpIfRole

cucsSwFcMonSrcEpIfRole

Module: CISCO-UNIFIED-COMPUTING-SW-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcMonSrcEpIfRole

OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.21.1.7

Node type: OBJECT-TYPE

Type: CucsNetworkPortRole

Access: read-only

Description: Cisco UCS sw:FcMonSrcEp:ifRole managed object property

What is cucsSwFcMonSrcEpIfRole?

This CucsNetworkPortRole field reports the interface role (for example uplink or server-facing) that the source endpoint whose traffic is being mirrored by an FC SPAN monitoring session is playing on the fabric. An admin checks ifRole to understand what function this specific FC interface serves, which changes how a fault on it should be interpreted. For example, a problem on an interface whose ifRole is uplink is a fabric-connectivity concern, while the same problem on a server-facing role points at a specific blade instead.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.21.1.7
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcMonSrcEpIfRole

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.21.1.7.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcMonSrcEpIfRole.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcMonSrcEpIfRole OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.46cucsSwObjectsCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.21cucsSwFcMonSrcEpTableCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.21.1cucsSwFcMonSrcEpEntryCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.21.1.7cucsSwFcMonSrcEpIfRoleCISCO-UNIFIED-COMPUTING-SW-MIB