CISCO-UNIFIED-COMPUTING-SW-MIB :: cucsSwFcMonRn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-SW-MIBcucsSwFcMonRn

cucsSwFcMonRn

Module: CISCO-UNIFIED-COMPUTING-SW-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcMonRn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.18.1.3

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS sw:FcMon:rn managed object property

What is cucsSwFcMonRn?

This OID returns the Relative Name (RN) of an FC traffic-monitoring (SPAN) session configured on a fabric interconnect to mirror Fibre Channel traffic for analysis, given as a SnmpAdminString — the naming fragment that distinguishes this instance from its sibling FcMon objects under the same parent in UCSM's object tree. Admins use the RN, combined with the parent's DN, to reconstruct exactly where this FcMon instance sits in the hierarchy without needing the full DN string on its own. For example, if two FcMon instances exist under the same parent object, their RNs are what differentiate row one from row two when UCSM lists both under that parent.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.18.1.3
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcMonRn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.18.1.3.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcMonRn.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcMonRn OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.46cucsSwObjectsCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.18cucsSwFcMonTableCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.18.1cucsSwFcMonEntryCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.18.1.3cucsSwFcMonRnCISCO-UNIFIED-COMPUTING-SW-MIB