All MIBs › CISCO-UNIFIED-COMPUTING-SW-MIB › cucsSwFcMonPeerDn
cucsSwFcMonPeerDn
Module: CISCO-UNIFIED-COMPUTING-SW-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcMonPeerDn
OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.18.1.22
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS sw:FcMon:peerDn managed object property
What is cucsSwFcMonPeerDn?
This SnmpAdminString field holds the Distinguished Name of the peer object connected to an FC traffic-monitoring (SPAN) session configured on a fabric interconnect to mirror Fibre Channel traffic for analysis on the other end of the link. An admin follows peerDn to identify exactly what is plugged into the other side of this connection, which is essential when tracing an FC link end-to-end. For example, if this endpoint's traffic drops, the admin uses peerDn to jump straight to the connected device or port and check its status too.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.18.1.22 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcMonPeerDn
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.18.1.22.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcMonPeerDn.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcMonPeerDn OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.46 | cucsSwObjects | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.18 | cucsSwFcMonTable | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.18.1 | cucsSwFcMonEntry | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.18.1.22 | cucsSwFcMonPeerDn | CISCO-UNIFIED-COMPUTING-SW-MIB |