All MIBs › CISCO-UNIFIED-COMPUTING-SW-MIB › cucsSwFcEstcEpSwitchId
cucsSwFcEstcEpSwitchId
Module: CISCO-UNIFIED-COMPUTING-SW-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcEstcEpSwitchId
OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.17.1.17
Node type: OBJECT-TYPE
Type: CucsNetworkSwitchId
Access: read-only
Description: Cisco UCS sw:FcEstcEp:switchId managed object property
What is cucsSwFcEstcEpSwitchId?
This CucsNetworkSwitchId value identifies which fabric interconnect switch (A or B) hosts an FC "established" endpoint — one FC-capable interface (uplink, FEX port, or similar) that UCSM has discovered and is tracking on the SAN fabric. An admin uses switchId to know which of the two redundant fabric interconnects a given SNMP row is reporting on, since UCS domains are normally dual-fabric. For example, if fabric A shows healthy values on this OID but fabric B's row shows a different switchId with a problem status, the admin knows the issue is isolated to one side of the redundant pair.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.17.1.17 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcEstcEpSwitchId
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.17.1.17.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcEstcEpSwitchId.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwFcEstcEpSwitchId OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.46 | cucsSwObjects | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.17 | cucsSwFcEstcEpTable | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.17.1 | cucsSwFcEstcEpEntry | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.17.1.17 | cucsSwFcEstcEpSwitchId | CISCO-UNIFIED-COMPUTING-SW-MIB |