All MIBs › CISCO-UNIFIED-COMPUTING-SW-MIB › cucsSwEthMonSrcEpIfRole
cucsSwEthMonSrcEpIfRole
Module: CISCO-UNIFIED-COMPUTING-SW-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthMonSrcEpIfRole
OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.15.1.7
Node type: OBJECT-TYPE
Type: CucsNetworkPortRole
Access: read-only
Description: Cisco UCS sw:EthMonSrcEp:ifRole managed object property
What is cucsSwEthMonSrcEpIfRole?
cucsSwEthMonSrcEpIfRole (syntax CucsNetworkPortRole) classifies the functional role (such as network uplink versus server-facing) that the interface behind this SPAN source endpoint plays. An admin checks this role to confirm the port is being used the way it was intended, since UCSM applies different configuration rules depending on whether an interface is acting as an uplink or a server-facing port. For example, if an interface expected to be a network uplink instead reports a server-facing role here, that mismatch would explain why an uplink configuration change failed to apply.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.15.1.7 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthMonSrcEpIfRole
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.15.1.7.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthMonSrcEpIfRole.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthMonSrcEpIfRole OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.46 | cucsSwObjects | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.15 | cucsSwEthMonSrcEpTable | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.15.1 | cucsSwEthMonSrcEpEntry | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.15.1.7 | cucsSwEthMonSrcEpIfRole | CISCO-UNIFIED-COMPUTING-SW-MIB |