All MIBs › CISCO-UNIFIED-COMPUTING-SW-MIB › cucsSwEthMonPeerDn
cucsSwEthMonPeerDn
Module: CISCO-UNIFIED-COMPUTING-SW-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthMonPeerDn
OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.12.1.22
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS sw:EthMon:peerDn managed object property
What is cucsSwEthMonPeerDn?
cucsSwEthMonPeerDn (syntax SnmpAdminString) holds the Distinguished Name of the corresponding object on the peer fabric interconnect that this SPAN monitoring session is paired with. An admin uses this to navigate directly to the matching configuration on the other fabric interconnect when comparing or reconciling settings across the redundant switch pair. For example, if the value this SPAN monitoring session reports differs from what its peer (identified by this DN) reports, that discrepancy points to a configuration drift between the two fabric interconnects.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.12.1.22 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthMonPeerDn
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.12.1.22.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthMonPeerDn.1
Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthMonPeerDn OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.46 | cucsSwObjects | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.12 | cucsSwEthMonTable | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.12.1 | cucsSwEthMonEntry | CISCO-UNIFIED-COMPUTING-SW-MIB |
| 1.3.6.1.4.1.9.9.719.1.46.12.1.22 | cucsSwEthMonPeerDn | CISCO-UNIFIED-COMPUTING-SW-MIB |