CISCO-UNIFIED-COMPUTING-SW-MIB :: cucsSwEthLanPcRecvFlowCtrl

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-SW-MIBcucsSwEthLanPcRecvFlowCtrl

cucsSwEthLanPcRecvFlowCtrl

Module: CISCO-UNIFIED-COMPUTING-SW-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthLanPcRecvFlowCtrl

OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.11.1.14

Node type: OBJECT-TYPE

Type: CucsFlowctrlFlowControl

Access: read-only

Description: Cisco UCS sw:EthLanPc:recvFlowCtrl managed object property

What is cucsSwEthLanPcRecvFlowCtrl?

cucsSwEthLanPcRecvFlowCtrl (syntax CucsFlowctrlFlowControl) reports whether this LAN uplink port channel is configured to honor received (RX) Ethernet pause frames from the far end. An admin checks this to confirm the port channel will slow down its own senders when the connected switch signals congestion, which affects whether traffic bursts get dropped or absorbed. For example, if a downstream switch is sending pause frames but this OID shows receive flow control disabled, those pause requests are being ignored and traffic loss could result.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.11.1.14
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthLanPcRecvFlowCtrl

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.11.1.14.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthLanPcRecvFlowCtrl.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsSwEthLanPcRecvFlowCtrl.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthLanPcRecvFlowCtrl OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.46cucsSwObjectsCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.11cucsSwEthLanPcTableCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.11.1cucsSwEthLanPcEntryCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.11.1.14cucsSwEthLanPcRecvFlowCtrlCISCO-UNIFIED-COMPUTING-SW-MIB