CISCO-UNIFIED-COMPUTING-SW-MIB :: cucsSwEthLanPcPriorityFlowCtrl

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-SW-MIBcucsSwEthLanPcPriorityFlowCtrl

cucsSwEthLanPcPriorityFlowCtrl

Module: CISCO-UNIFIED-COMPUTING-SW-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthLanPcPriorityFlowCtrl

OID (numeric): 1.3.6.1.4.1.9.9.719.1.46.11.1.13

Node type: OBJECT-TYPE

Type: CucsFlowctrlPriorityPause

Access: read-only

Description: Cisco UCS sw:EthLanPc:priorityFlowCtrl managed object property

What is cucsSwEthLanPcPriorityFlowCtrl?

cucsSwEthLanPcPriorityFlowCtrl (syntax CucsFlowctrlPriorityPause) reports the priority-based flow control (PFC) pause configuration applied to this LAN uplink port channel. An admin checks this setting to confirm lossless, priority-tagged traffic classes on this LAN uplink port channel are configured to pause correctly under congestion rather than dropping frames. For example, if storage traffic sharing this uplink starts experiencing drops, an admin would check this OID to confirm priority flow control is actually enabled as expected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.11.1.13
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthLanPcPriorityFlowCtrl

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.46.11.1.13.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthLanPcPriorityFlowCtrl.1

Start monitoring Cisco UCS fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-SW-MIB::cucsSwEthLanPcPriorityFlowCtrl OID value, configure state conditions and alerts, and monitor any Cisco UCS fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.46cucsSwObjectsCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.11cucsSwEthLanPcTableCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.11.1cucsSwEthLanPcEntryCISCO-UNIFIED-COMPUTING-SW-MIB
1.3.6.1.4.1.9.9.719.1.46.11.1.13cucsSwEthLanPcPriorityFlowCtrlCISCO-UNIFIED-COMPUTING-SW-MIB