CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageVirtualDriveRefRn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageVirtualDriveRefRn

cucsStorageVirtualDriveRefRn

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveRefRn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.91.1.3

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS storage:VirtualDriveRef:rn managed object property

What is cucsStorageVirtualDriveRefRn?

This string is the Relative Name (Rn) of a reference record that a boot policy or storage profile keeps to a specific RAID virtual drive, capturing that virtual drive's identity and settings as pinned into the boot order, the naming property that distinguishes this particular VirtualDriveRef instance from its sibling instances under the same parent object. It matters operationally because the Rn is the last segment appended to the parent's Dn to build this object's own Dn, so it tells an admin exactly which sibling (which slot, index, or identifier) this row describes. For instance, comparing the Rn values under one parent object lets an admin quickly enumerate every VirtualDriveRef instance attached to that parent without decoding the full Dn each time.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.91.1.3
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveRefRn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.91.1.3.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveRefRn.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveRefRn OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.91cucsStorageVirtualDriveRefTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.91.1cucsStorageVirtualDriveRefEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.91.1.3cucsStorageVirtualDriveRefRnCISCO-UNIFIED-COMPUTING-STORAGE-MIB