CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageVirtualDriveRefDiskSelectionOrder

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageVirtualDriveRefDiskSelectionOrder

cucsStorageVirtualDriveRefDiskSelectionOrder

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveRefDiskSelectionOrder

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.91.1.7

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS storage:VirtualDriveRef:diskSelectionOrder managed object property

What is cucsStorageVirtualDriveRefDiskSelectionOrder?

This Gauge32 records the disk-selection order recorded on the VirtualDriveRef, i.e. the sequence in which physical disks were chosen to build the referenced RAID virtual drive. An admin cares about this when validating that a storage profile's disk-group policy picked disks in the intended order, which affects which physical disks a given virtual drive spans. For example, comparing diskSelectionOrder across two virtual drives on the same server confirms they were built from disjoint sets of physical disks rather than overlapping selections.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.91.1.7
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveRefDiskSelectionOrder

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.91.1.7.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveRefDiskSelectionOrder.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsStorageVirtualDriveRefDiskSelectionOrder.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveRefDiskSelectionOrder OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.91cucsStorageVirtualDriveRefTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.91.1cucsStorageVirtualDriveRefEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.91.1.7cucsStorageVirtualDriveRefDiskSelectionOrderCISCO-UNIFIED-COMPUTING-STORAGE-MIB