All MIBs › CISCO-UNIFIED-COMPUTING-STORAGE-MIB › cucsStorageVirtualDrivePresence
cucsStorageVirtualDrivePresence
Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDrivePresence
OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.31.1.11
Node type: OBJECT-TYPE
Type: CucsEquipmentPresence
Access: read-only
Description: Cisco UCS storage:VirtualDrive:presence managed object property
What is cucsStorageVirtualDrivePresence?
This CucsEquipmentPresence value reports whether a virtual drive is currently detected as present by its controller. An admin uses this field to confirm a configured virtual drive still exists and hasn't been unexpectedly removed or deleted. For example, if an expected virtual drive suddenly shows as absent in this presence field, the admin investigates whether the RAID configuration was inadvertently changed.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.31.1.11 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDrivePresence
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.31.1.11.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDrivePresence.1
Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDrivePresence OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.45 | cucsStorageObjects | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.31 | cucsStorageVirtualDriveTable | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.31.1 | cucsStorageVirtualDriveEntry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.31.1.11 | cucsStorageVirtualDrivePresence | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |