All MIBs › CISCO-UNIFIED-COMPUTING-STORAGE-MIB › cucsStorageVirtualDriveEpOperDeviceId
cucsStorageVirtualDriveEpOperDeviceId
Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveEpOperDeviceId
OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.115.1.10
Node type: OBJECT-TYPE
Type: Gauge32
Access: read-only
Description: Cisco UCS storage:VirtualDriveEp:operDeviceId managed object property
What is cucsStorageVirtualDriveEpOperDeviceId?
This Gauge32 value reports the operational device identifier for a virtual drive as seen at its controller-side endpoint. An admin uses this endpoint-level device id to correlate the controller's own device numbering with UCSM's logical drive record. For example, when troubleshooting a driver-level device enumeration issue, the admin matches this operDeviceId to the OS-reported device number for that drive.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.115.1.10 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveEpOperDeviceId
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.115.1.10.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveEpOperDeviceId.1
Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveEpOperDeviceId OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.45 | cucsStorageObjects | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.115 | cucsStorageVirtualDriveEpTable | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.115.1 | cucsStorageVirtualDriveEpEntry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.115.1.10 | cucsStorageVirtualDriveEpOperDeviceId | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |