CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageVirtualDriveAdminActionTrigger

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageVirtualDriveAdminActionTrigger

cucsStorageVirtualDriveAdminActionTrigger

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveAdminActionTrigger

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.31.1.27

Node type: OBJECT-TYPE

Type: CucsStorageAdminActionTrigger

Access: read-only

Description: Cisco UCS storage:VirtualDrive:adminActionTrigger managed object property

What is cucsStorageVirtualDriveAdminActionTrigger?

This CucsStorageAdminActionTrigger value indicates an administrative action requested to be performed on a virtual drive, such as initiating a specific maintenance operation. An admin sets this field to trigger that action and then monitors it to confirm the requested operation was picked up by UCSM. For example, an admin triggers a virtual drive initialization through this field and then polls related state fields to confirm the action executed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.31.1.27
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveAdminActionTrigger

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.31.1.27.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveAdminActionTrigger.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageVirtualDriveAdminActionTrigger OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.31cucsStorageVirtualDriveTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.31.1cucsStorageVirtualDriveEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.31.1.27cucsStorageVirtualDriveAdminActionTriggerCISCO-UNIFIED-COMPUTING-STORAGE-MIB