CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageTransportableFlashModulePresence

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageTransportableFlashModulePresence

cucsStorageTransportableFlashModulePresence

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageTransportableFlashModulePresence

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.33.1.11

Node type: OBJECT-TYPE

Type: CucsEquipmentPresence

Access: read-only

Description: Cisco UCS storage:TransportableFlashModule:presence managed object property

What is cucsStorageTransportableFlashModulePresence?

This CucsEquipmentPresence value reports whether a transportable flash module is physically detected as present in its slot. An admin uses this field to confirm hardware presence, distinguishing a genuinely missing module from one that is present but reporting a fault. For example, if a slot expected to hold a flash module instead shows this presence field as absent, the admin knows the module was physically removed or never seated correctly.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.33.1.11
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageTransportableFlashModulePresence

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.33.1.11.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageTransportableFlashModulePresence.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageTransportableFlashModulePresence OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.33cucsStorageTransportableFlashModuleTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.33.1cucsStorageTransportableFlashModuleEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.33.1.11cucsStorageTransportableFlashModulePresenceCISCO-UNIFIED-COMPUTING-STORAGE-MIB