All MIBs › CISCO-UNIFIED-COMPUTING-STORAGE-MIB › cucsStorageSystemFsmTry
cucsStorageSystemFsmTry
Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageSystemFsmTry
OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.27.1.13
Node type: OBJECT-TYPE
Type: Gauge32
Access: read-only
Description: Cisco UCS storage:System:fsmTry managed object property
What is cucsStorageSystemFsmTry?
This Gauge32 value counts the number of retry attempts the storage System object's FSM task has made at its current stage. An admin watches this retry count to identify a storage workflow that is repeatedly failing and retrying rather than progressing normally. For example, a climbing fsmTry count on a storage inventory task signals the admin that the underlying operation keeps failing and needs manual troubleshooting.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.27.1.13 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageSystemFsmTry
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.27.1.13.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageSystemFsmTry.1
Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageSystemFsmTry OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.45 | cucsStorageObjects | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.27 | cucsStorageSystemTable | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.27.1 | cucsStorageSystemEntry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.27.1.13 | cucsStorageSystemFsmTry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |