CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageRaidBatteryConnectionProtocol

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageRaidBatteryConnectionProtocol

cucsStorageRaidBatteryConnectionProtocol

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageRaidBatteryConnectionProtocol

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.11.1.5

Node type: OBJECT-TYPE

Type: CucsStorageConnectionProtocol

Access: read-only

Description: Cisco UCS storage:RaidBattery:connectionProtocol managed object property

What is cucsStorageRaidBatteryConnectionProtocol?

This object reports the connection protocol, per the CucsStorageConnectionProtocol enumeration, used by a RAID controller's battery backup unit. An admin uses this to confirm the battery communicates with the controller over the expected protocol, relevant when diagnosing why a battery isn't being detected correctly. For example, if the RAID controller fails to report battery status, the admin checks this protocol value to rule out a communication-interface issue.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.11.1.5
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageRaidBatteryConnectionProtocol

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.11.1.5.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageRaidBatteryConnectionProtocol.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageRaidBatteryConnectionProtocol OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.11cucsStorageRaidBatteryTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.11.1cucsStorageRaidBatteryEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.11.1.5cucsStorageRaidBatteryConnectionProtocolCISCO-UNIFIED-COMPUTING-STORAGE-MIB