All MIBs › CISCO-UNIFIED-COMPUTING-STORAGE-MIB › cucsStorageLocalDiskSlotEpConfiguration
cucsStorageLocalDiskSlotEpConfiguration
Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskSlotEpConfiguration
OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.13.1.4
Node type: OBJECT-TYPE
Type: CucsStorageConfiguration
Access: read-only
Description: Cisco UCS storage:LocalDiskSlotEp:configuration managed object property
What is cucsStorageLocalDiskSlotEpConfiguration?
This OID reports the configuration state of this drive-bay slot. This tells an admin whether the slot has been configured for a particular use, such as being reserved for a specific RAID role, independent of the physical disk's own status. If a newly inserted disk does not behave as expected, an admin would check this configuration field to confirm the slot itself was configured correctly beforehand.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.13.1.4 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskSlotEpConfiguration
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.13.1.4.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskSlotEpConfiguration.1
Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskSlotEpConfiguration OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.45 | cucsStorageObjects | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.13 | cucsStorageLocalDiskSlotEpTable | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.13.1 | cucsStorageLocalDiskSlotEpEntry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.13.1.4 | cucsStorageLocalDiskSlotEpConfiguration | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |