CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageLocalDiskPresence

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageLocalDiskPresence

cucsStorageLocalDiskPresence

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskPresence

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.4.1.10

Node type: OBJECT-TYPE

Type: CucsEquipmentPresence

Access: read-only

Description: Cisco UCS storage:LocalDisk:presence managed object property

What is cucsStorageLocalDiskPresence?

This OID reports whether this local disk slot is currently occupied and recognized by UCS Manager. This tells an admin, independent of the drive's health, whether a physical disk is even seated in that bay, which is important for distinguishing a disk that has been removed from one that is present but failed. If a drive bay shows no data at all in monitoring, an admin would check this field to confirm whether a disk was ever actually inserted in that slot.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.4.1.10
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskPresence

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.4.1.10.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskPresence.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskPresence OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.4cucsStorageLocalDiskTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.4.1cucsStorageLocalDiskEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.4.1.10cucsStorageLocalDiskPresenceCISCO-UNIFIED-COMPUTING-STORAGE-MIB