CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageLocalDiskEpEncId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageLocalDiskEpEncId

cucsStorageLocalDiskEpEncId

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskEpEncId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.60.1.5

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS storage:LocalDiskEp:encId managed object property

What is cucsStorageLocalDiskEpEncId?

This OID reports the enclosure identifier associated with this physical disk endpoint. This tells an admin which physical drive enclosure, main chassis or attached expansion, the disk actually resides in, useful when troubleshooting an enclosure-wide connectivity issue. If several disks in the same enclosure fail simultaneously, an admin would confirm via this enclosure Id that they indeed share the same enclosure before suspecting a shared hardware fault.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.60.1.5
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskEpEncId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.60.1.5.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskEpEncId.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskEpEncId OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.60cucsStorageLocalDiskEpTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.60.1cucsStorageLocalDiskEpEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.60.1.5cucsStorageLocalDiskEpEncIdCISCO-UNIFIED-COMPUTING-STORAGE-MIB