CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageLocalDiskConfigPolicyFlexFlashRAIDReportingState

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageLocalDiskConfigPolicyFlexFlashRAIDReportingState

cucsStorageLocalDiskConfigPolicyFlexFlashRAIDReportingState

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskConfigPolicyFlexFlashRAIDReportingState

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.6.1.11

Node type: OBJECT-TYPE

Type: CucsStorageLocalDiskConfigFlexFlashRAIDReportingState

Access: read-only

Description: Cisco UCS storage:LocalDiskConfigPolicy:flexFlashRAIDReportingSta te managed object property

What is cucsStorageLocalDiskConfigPolicyFlexFlashRAIDReportingState?

This OID reports the RAID-reporting state for FlexFlash storage as configured by this shared local-disk policy. This controls, fleet-wide for every profile using this policy, whether FlexFlash mirror health alerts are actively reported to the admin. If FlexFlash mirror degradation alerts are not appearing anywhere in the environment, an admin would check this field on their shared policy to confirm reporting was not disabled at the policy level.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.6.1.11
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskConfigPolicyFlexFlashRAIDReportingState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.6.1.11.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskConfigPolicyFlexFlashRAIDReportingState.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskConfigPolicyFlexFlashRAIDReportingState OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.6cucsStorageLocalDiskConfigPolicyTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.6.1cucsStorageLocalDiskConfigPolicyEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.6.1.11cucsStorageLocalDiskConfigPolicyFlexFlashRAIDReportingStateCISCO-UNIFIED-COMPUTING-STORAGE-MIB