CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageLocalDiskConfigDefMode

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageLocalDiskConfigDefMode

cucsStorageLocalDiskConfigDefMode

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskConfigDefMode

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.5.1.6

Node type: OBJECT-TYPE

Type: CucsStorageLocalDiskMode

Access: read-only

Description: Cisco UCS storage:LocalDiskConfigDef:mode managed object property

What is cucsStorageLocalDiskConfigDefMode?

This OID reports the configured local-disk mode, such as RAID-1 mirrored, RAID-0 striped, or no local storage, defined by this configuration definition. This is the actual setting an admin edits to control how the server's local disks should be configured, which directly determines redundancy and available capacity for that service profile. If a server's local disks are not mirroring as expected, an admin would check this mode field to confirm the service profile is actually set to a mirrored mode rather than defaulting to unconfigured.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.5.1.6
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskConfigDefMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.5.1.6.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskConfigDefMode.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskConfigDefMode OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.5cucsStorageLocalDiskConfigDefTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.5.1cucsStorageLocalDiskConfigDefEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.5.1.6cucsStorageLocalDiskConfigDefModeCISCO-UNIFIED-COMPUTING-STORAGE-MIB