CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageHddMotherBoardTempStatsSuspect

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageHddMotherBoardTempStatsSuspect

cucsStorageHddMotherBoardTempStatsSuspect

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsSuspect

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.112.1.23

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Cisco UCS storage:HddMotherBoardTempStats:suspect managed object property

What is cucsStorageHddMotherBoardTempStatsSuspect?

This is a true/false flag on the HddMotherBoardTempStats object indicating whether UCS Manager considers this particular temperature sample unreliable. An admin should treat any accompanying temperature readings with caution when this flag is set, since a suspect sample means the collection process itself, not necessarily the hardware, may be the source of an odd value, so alarms should not be trusted at face value. For example, if the right-outlet temperature jumps implausibly high in one polling cycle but this Suspect flag is true for that same sample, the admin would wait for the next clean sample rather than immediately escalating a thermal event.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.112.1.23
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsSuspect

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.112.1.23.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsSuspect.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsSuspect OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.112cucsStorageHddMotherBoardTempStatsTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.112.1cucsStorageHddMotherBoardTempStatsEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.112.1.23cucsStorageHddMotherBoardTempStatsSuspectCISCO-UNIFIED-COMPUTING-STORAGE-MIB