CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageHddMotherBoardTempStatsRightInletTemp

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageHddMotherBoardTempStatsRightInletTemp

cucsStorageHddMotherBoardTempStatsRightInletTemp

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsRightInletTemp

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.112.1.14

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS storage:HddMotherBoardTempStats:rightInletTemp managed object property

What is cucsStorageHddMotherBoardTempStatsRightInletTemp?

This reports the current temperature reading, in degrees Celsius, at the right inlet sensor of this storage enclosure's HDD motherboard. An admin compares this to the left inlet reading to check whether cooling airflow is even across both sides of the board. A rightInletTemp noticeably higher than leftInletTemp on the same enclosure would point an admin toward uneven airflow or a partially blocked vent on that side.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.112.1.14
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsRightInletTemp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.112.1.14.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsRightInletTemp.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsStorageHddMotherBoardTempStatsRightInletTemp.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsRightInletTemp OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.112cucsStorageHddMotherBoardTempStatsTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.112.1cucsStorageHddMotherBoardTempStatsEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.112.1.14cucsStorageHddMotherBoardTempStatsRightInletTempCISCO-UNIFIED-COMPUTING-STORAGE-MIB