All MIBs › CISCO-UNIFIED-COMPUTING-STORAGE-MIB › cucsStorageHddMotherBoardTempStatsRightInletTemp
cucsStorageHddMotherBoardTempStatsRightInletTemp
Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsRightInletTemp
OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.112.1.14
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Cisco UCS storage:HddMotherBoardTempStats:rightInletTemp managed object property
What is cucsStorageHddMotherBoardTempStatsRightInletTemp?
This reports the current temperature reading, in degrees Celsius, at the right inlet sensor of this storage enclosure's HDD motherboard. An admin compares this to the left inlet reading to check whether cooling airflow is even across both sides of the board. A rightInletTemp noticeably higher than leftInletTemp on the same enclosure would point an admin toward uneven airflow or a partially blocked vent on that side.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.112.1.14 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsRightInletTemp
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.112.1.14.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsRightInletTemp.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsStorageHddMotherBoardTempStatsRightInletTemp.1
Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsRightInletTemp OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.45 | cucsStorageObjects | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.112 | cucsStorageHddMotherBoardTempStatsTable | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.112.1 | cucsStorageHddMotherBoardTempStatsEntry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.112.1.14 | cucsStorageHddMotherBoardTempStatsRightInletTemp | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |