All MIBs › CISCO-UNIFIED-COMPUTING-STORAGE-MIB › cucsStorageHddMotherBoardTempStatsLeftInletTemp
cucsStorageHddMotherBoardTempStatsLeftInletTemp
Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsLeftInletTemp
OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.112.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Cisco UCS storage:HddMotherBoardTempStats:leftInletTemp managed object property
What is cucsStorageHddMotherBoardTempStatsLeftInletTemp?
This reports the current temperature reading, in degrees Celsius, at the left inlet sensor of this storage enclosure's HDD motherboard. An admin monitors this to catch rising intake air temperature on the drive-bearing motherboard before it stresses the disks it cools. A leftInletTemp that climbs well above the enclosure's normal baseline would prompt an admin to check the data center's cooling or airflow around that enclosure.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.112.1.5 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsLeftInletTemp
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.112.1.5.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsLeftInletTemp.1
Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsLeftInletTemp OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.45 | cucsStorageObjects | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.112 | cucsStorageHddMotherBoardTempStatsTable | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.112.1 | cucsStorageHddMotherBoardTempStatsEntry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.112.1.5 | cucsStorageHddMotherBoardTempStatsLeftInletTemp | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |