CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageHddMotherBoardTempStatsHistRightOutletTempMax

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageHddMotherBoardTempStatsHistRightOutletTempMax

cucsStorageHddMotherBoardTempStatsHistRightOutletTempMax

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsHistRightOutletTempMax

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.113.1.20

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS storage:HddMotherBoardTempStatsHist:rightOutletTempMax managed object property

What is cucsStorageHddMotherBoardTempStatsHistRightOutletTempMax?

This OID captures the peak right-outlet temperature that occurred during the interval of this archived sample. This preserved maximum is what an admin cites as evidence when justifying a fan or airflow remediation ticket for a specific disk bay, since it shows the actual worst-case temperature that was reached. If this Max value for several consecutive historical records keeps climbing, that trend alone, even without any current alarm, would justify proactive fan replacement before a real overheat event occurs.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.113.1.20
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsHistRightOutletTempMax

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.113.1.20.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsHistRightOutletTempMax.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsHistRightOutletTempMax OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.113cucsStorageHddMotherBoardTempStatsHistTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.113.1cucsStorageHddMotherBoardTempStatsHistEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.113.1.20cucsStorageHddMotherBoardTempStatsHistRightOutletTempMaxCISCO-UNIFIED-COMPUTING-STORAGE-MIB