CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageHddMotherBoardTempStatsHistRightOutletTempAvg

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageHddMotherBoardTempStatsHistRightOutletTempAvg

cucsStorageHddMotherBoardTempStatsHistRightOutletTempAvg

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsHistRightOutletTempAvg

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.113.1.19

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS storage:HddMotherBoardTempStatsHist:rightOutletTempAvg managed object property

What is cucsStorageHddMotherBoardTempStatsHistRightOutletTempAvg?

This OID holds the averaged right-outlet temperature value from this archived history sample. Averaging historical outlet readings gives an admin a cleaner baseline of normal operating temperature for that disk bay to compare future readings against. If a replacement disk's live outlet readings run well above this archived average baseline from before, that discrepancy would prompt an admin to check the new drive's seating or the fan configuration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.113.1.19
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsHistRightOutletTempAvg

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.113.1.19.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsHistRightOutletTempAvg.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsHistRightOutletTempAvg OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.113cucsStorageHddMotherBoardTempStatsHistTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.113.1cucsStorageHddMotherBoardTempStatsHistEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.113.1.19cucsStorageHddMotherBoardTempStatsHistRightOutletTempAvgCISCO-UNIFIED-COMPUTING-STORAGE-MIB