CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageHddMotherBoardTempStatsHistLeftInletTemp

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageHddMotherBoardTempStatsHistLeftInletTemp

cucsStorageHddMotherBoardTempStatsHistLeftInletTemp

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsHistLeftInletTemp

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.113.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS storage:HddMotherBoardTempStatsHist:leftInletTemp managed object property

What is cucsStorageHddMotherBoardTempStatsHistLeftInletTemp?

This OID stores the archived left-inlet temperature reading captured for the HDD motherboard at the time this history record was collected. The inlet-side reading tells an admin how hot the air was entering that side of the disk backboard, which matters for judging whether an upstream heat source, like a neighboring component, is pre-heating cooling air before it even reaches this drive. Comparing a run of these historical left-inlet records for one disk bay would let an admin see whether ambient rack temperature, not the drive itself, is driving up local readings over time.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.113.1.5
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsHistLeftInletTemp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.113.1.5.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsHistLeftInletTemp.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsStorageHddMotherBoardTempStatsHistLeftInletTemp.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsHistLeftInletTemp OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.113cucsStorageHddMotherBoardTempStatsHistTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.113.1cucsStorageHddMotherBoardTempStatsHistEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.113.1.5cucsStorageHddMotherBoardTempStatsHistLeftInletTempCISCO-UNIFIED-COMPUTING-STORAGE-MIB