All MIBs › CISCO-UNIFIED-COMPUTING-STORAGE-MIB › cucsStorageHddMotherBoardTempStatsDn
cucsStorageHddMotherBoardTempStatsDn
Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsDn
OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.112.1.2
Node type: OBJECT-TYPE
Type: CucsManagedObjectDn
Access: read-only
Description: Cisco UCS storage:HddMotherBoardTempStats:dn managed object property
What is cucsStorageHddMotherBoardTempStatsDn?
This is the Distinguished Name (Dn) of the HddMotherBoardTempStats object — the full UCS Manager tree path identifying this periodic temperature-sensor stats sample from a storage enclosure's HDD motherboard. An admin uses this Dn to know exactly which storage enclosure's HDD motherboard a given temperature-stats row belongs to, since each enclosure reports its own sample. The Dn for the HDD motherboard temperature stats on one storage enclosure would differ from the Dn of the stats on a different enclosure in the same chassis.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.112.1.2 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsDn
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.112.1.2.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsDn.1
Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageHddMotherBoardTempStatsDn OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.45 | cucsStorageObjects | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.112 | cucsStorageHddMotherBoardTempStatsTable | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.112.1 | cucsStorageHddMotherBoardTempStatsEntry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.112.1.2 | cucsStorageHddMotherBoardTempStatsDn | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |