All MIBs › CISCO-UNIFIED-COMPUTING-STORAGE-MIB › cucsStorageFlexFlashVirtualDriveType
cucsStorageFlexFlashVirtualDriveType
Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashVirtualDriveType
OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.37.1.17
Node type: OBJECT-TYPE
Type: CucsStorageLunType
Access: read-only
Description: Cisco UCS storage:FlexFlashVirtualDrive:type managed object property
What is cucsStorageFlexFlashVirtualDriveType?
This reports the CucsStorageLunType of this FlexFlash virtual drive, classifying the kind of logical unit the controller presents to the host. An admin uses this to confirm the virtual drive is being presented in the expected LUN type for the OS or hypervisor to recognize it correctly. If the OS fails to recognize the embedded storage, checking this type value helps confirm whether the LUN presentation matches what the OS driver expects.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.37.1.17 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashVirtualDriveType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.37.1.17.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashVirtualDriveType.1
Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashVirtualDriveType OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.45 | cucsStorageObjects | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.37 | cucsStorageFlexFlashVirtualDriveTable | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.37.1 | cucsStorageFlexFlashVirtualDriveEntry | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |
| 1.3.6.1.4.1.9.9.719.1.45.37.1.17 | cucsStorageFlexFlashVirtualDriveType | CISCO-UNIFIED-COMPUTING-STORAGE-MIB |