CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageFlexFlashVirtualDrivePresence

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageFlexFlashVirtualDrivePresence

cucsStorageFlexFlashVirtualDrivePresence

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashVirtualDrivePresence

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.37.1.11

Node type: OBJECT-TYPE

Type: CucsEquipmentPresence

Access: read-only

Description: Cisco UCS storage:FlexFlashVirtualDrive:presence managed object property

What is cucsStorageFlexFlashVirtualDrivePresence?

This reports the CucsEquipmentPresence of this FlexFlash virtual drive — whether the controller is currently presenting a virtual drive to the host at all. An admin checks this to confirm the controller has successfully assembled its physical cards into a usable virtual drive, rather than exposing nothing. If both physical cards are present but this virtual drive still reports 'missing' presence, that points to a controller-level assembly problem.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.37.1.11
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashVirtualDrivePresence

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.37.1.11.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashVirtualDrivePresence.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashVirtualDrivePresence OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.37cucsStorageFlexFlashVirtualDriveTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.37.1cucsStorageFlexFlashVirtualDriveEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.37.1.11cucsStorageFlexFlashVirtualDrivePresenceCISCO-UNIFIED-COMPUTING-STORAGE-MIB