CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageFlexFlashVirtualDriveNumberOfBlocks

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageFlexFlashVirtualDriveNumberOfBlocks

cucsStorageFlexFlashVirtualDriveNumberOfBlocks

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashVirtualDriveNumberOfBlocks

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.37.1.8

Node type: OBJECT-TYPE

Type: Unsigned64

Access: read-only

Description: Cisco UCS storage:FlexFlashVirtualDrive:numberOfBlocks managed object property

What is cucsStorageFlexFlashVirtualDriveNumberOfBlocks?

This reports the total number of addressable blocks on this FlexFlash virtual drive as presented to the host. An admin uses this, combined with block size, to determine the usable capacity of the embedded storage the OS actually sees. This number reflects the virtual drive's effective capacity, which in a mirrored configuration matches the smaller of the two underlying physical cards, not their combined total.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.37.1.8
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashVirtualDriveNumberOfBlocks

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.37.1.8.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashVirtualDriveNumberOfBlocks.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashVirtualDriveNumberOfBlocks OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.37cucsStorageFlexFlashVirtualDriveTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.37.1cucsStorageFlexFlashVirtualDriveEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.37.1.8cucsStorageFlexFlashVirtualDriveNumberOfBlocksCISCO-UNIFIED-COMPUTING-STORAGE-MIB