CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageFlexFlashDriveVisible

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageFlexFlashDriveVisible

cucsStorageFlexFlashDriveVisible

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveVisible

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.36.1.21

Node type: OBJECT-TYPE

Type: CucsStorageFFDriveVisible

Access: read-only

Description: Cisco UCS storage:FlexFlashDrive:visible managed object property

What is cucsStorageFlexFlashDriveVisible?

This reports the CucsStorageFFDriveVisible flag for this physical FlexFlash drive, indicating whether it is currently exposed as visible to the host OS. An admin checks this when the OS fails to see an expected drive, to determine whether the controller is deliberately hiding it rather than the drive being absent. If visible is false for a drive an admin expects the OS to use, that explains why the OS reports missing storage even though the drive is physically present.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.36.1.21
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveVisible

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.36.1.21.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveVisible.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveVisible OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.36cucsStorageFlexFlashDriveTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.36.1cucsStorageFlexFlashDriveEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.36.1.21cucsStorageFlexFlashDriveVisibleCISCO-UNIFIED-COMPUTING-STORAGE-MIB