CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageFlexFlashDriveRn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageFlexFlashDriveRn

cucsStorageFlexFlashDriveRn

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveRn

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.36.1.3

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS storage:FlexFlashDrive:rn managed object property

What is cucsStorageFlexFlashDriveRn?

This is the Relative Name (Rn) of the FlexFlashDrive object — the naming fragment that distinguishes this physical drive from its sibling drive under the same FlexFlash controller. An admin uses the Rn to tell apart the two physical FlexFlash drives typically present under the same controller. The two physical drives under the same controller would carry different Rn values while sharing the same parent path.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.36.1.3
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveRn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.36.1.3.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveRn.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveRn OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.36cucsStorageFlexFlashDriveTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.36.1cucsStorageFlexFlashDriveEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.36.1.3cucsStorageFlexFlashDriveRnCISCO-UNIFIED-COMPUTING-STORAGE-MIB