CISCO-UNIFIED-COMPUTING-STORAGE-MIB :: cucsStorageFlexFlashDriveName

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-STORAGE-MIBcucsStorageFlexFlashDriveName

cucsStorageFlexFlashDriveName

Module: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveName

OID (numeric): 1.3.6.1.4.1.9.9.719.1.45.36.1.11

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS storage:FlexFlashDrive:name managed object property

What is cucsStorageFlexFlashDriveName?

This reports the name UCSM assigns to this physical FlexFlash drive slot. An admin uses this name to match the SNMP row to the physical drive shown in UCS Manager's own GUI when planning maintenance. This might read something like 'FlexFlash-1' to distinguish it from a sibling drive named 'FlexFlash-2' under the same controller.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.36.1.11
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveName

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.45.36.1.11.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveName.1

Start monitoring Cisco UCS (Unified Computing System) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageFlexFlashDriveName OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.45cucsStorageObjectsCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.36cucsStorageFlexFlashDriveTableCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.36.1cucsStorageFlexFlashDriveEntryCISCO-UNIFIED-COMPUTING-STORAGE-MIB
1.3.6.1.4.1.9.9.719.1.45.36.1.11cucsStorageFlexFlashDriveNameCISCO-UNIFIED-COMPUTING-STORAGE-MIB